Diese Seite beschreibt die nötigen Schritte, um einen Dell Poweredge 1950 oder 2950 zu installieren.
Contents
Remote Access Konfiguration
Hier nutzt man die Voreinstellung der DRAC5-Karte. Nachdem Notebook und DRAC5-Port verbunden sind:
# /sbin/ifconfig eth0 up 192.168.0.1 netmask 255.255.255.0 # ssh 192.168.0.120
Login as root, password: calvin .
$ racadm setniccfg -s <IP> <Netmask> <Gateway>
Dann Ausloggen und den DRAC5 (wieder) an den Switch anschließen. Nach ein paar Sekunden ist er unter der neuen Adresse erreichbar.
BIOS
CPU Virtualisierungserweiterungen aktivieren
Automatisches Booten per PXE deaktivieren
Ungenutzte NICs deaktivieren
LCD-Anzeige
Stromspar-Einstellungen
Automatisches Einschalten nach Stromausfall deaktivieren
Keine Keyboard-Fehler